Mg 1000b platform configuration overview – Nortel Networks NN43001-314 User Manual

Page 44

Advertising
background image

44

Overview

Multi Server (CP-P4) Port Network Configuration (Dual-homing -
Distributed), shows a configuration with a Call Server platform that does not
reside in a MG 1000B cabinet and chassis; therefore no direct connection
exists to the MGC. The CP-P4 call server does not use the MGC dual
homing feature to increase the system reliability

Figure 10
Multi server (CP-P4) port network configuration (dual-homing - distributed)

MG 1000B platform configuration overview

In each MG 1000B Core, one CP PM and MGC is required. The three
remaining slots (nine in an MG 1000B Cabinet) can contain analog line
cards, analog trunk cards, digital line cards, or digital trunk cards. Refer to

Table 3 "Card slots for MG 1000B Core and MG 1000B Expander" (page
32)

for a summary of the allowable card slots.

Each MG 1000B Core with a digital trunk card must have a clock controller.
See Circuit Card Reference(NN43001-311)

For further information on line side T1 and line side E1 cards, refer to

There are two configurations for the MG 1000B platform:

without an MG 1000B Expander

with an MG 1000B Expander

Nortel Communication Server 1000

Branch Office Installation and Commissioning

NN43001-314

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2007, Nortel Networks

.

Advertising