Converting a Small System to a Branch Office

2

For each Small System that is to be converted to a Branch Office:

a. Power down the system, including reserve power if so equipped.

b. Upgrade the system controller card if required. Refer to Meridian

1 Small System Software -only Upgrade (NN43011-459).

c. Install a Voice Gateway Media Card if required. Refer to IP Line

Fundamentals (NN43100-500).

If the Small System already has a Voice Gateway Media Card,
upgrade it to IP Line 4.5. Refer to IP Line Fundamentals
(NN43100-500)
.

d. Install a Signaling Server if required. Follow the procedures in

"Installing a Signaling Server" (page 228)

.

A Signaling Server must be installed on an Meridian Option
11C/Meridian 1 PBX 11C Cabinet, or Meridian Option 11C
Mini/Meridian 1 PBX 11C Chassis system. A CS 1000M Small
System already has a Signaling Server installed.

e. Configure the Signaling Server.

1. Run the Signaling Server Install Tool, as described in

Installing the Signaling Server software

.

2. Transfer the node information using Element Manager. Refer

to IP Line Fundamentals (NN43100-500).

f.

Install the Branch Office software, using the Branch Office
keycodes. Follow

Installing and provisioning an MG 1000B

. At

the specified menus, select the following:

1. At the Branch Office Software Installation Main Menu (

step

1

), select the following option:

3.

New System Installation — From Software

Delivery Card

2. At the Select Database menu (

step 8

), select the following

option to use the existing database:

3.

Archived database

The software for a Branch Office is significantly different from the
software for a Small System.

g. Configure the Branch Office (Customer Data Block and ELAN

subnet). See

Procedure 23 "Configuring the MG 1000B zone"

(page 257)

.

h. Configure the Branch Office dialing plan. See

"Dialing plan

configuration" (page 291)

.

Nortel Communication Server 1000

Branch Office Installation and Commissioning

NN43001-314

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2007, Nortel Networks

.