Installing a Signaling Server

237

2. Gently pull the tabs out and down to swing open the hinged

bezel door.

Figure 84
Signaling Server with open bezel door

The MAC addresses are visible on the lower right-hand side
when the bezel door is open. See

Figure 85 "MAC address"

(page 237)

.

MAC1 is Port 1 (ELAN network interface), and MAC2 is Port 2
(TLAN network interface).

Though the MAC1 address is the top address, Port 1 is the
bottom network interface port on the back of the Signaling Server.

Figure 86 "Signaling Server indicators and power switch" (page
238)

shows the LEDs that correspond to the ELAN and TLAN

network interfaces.

Figure 85
MAC address

b. Press the Power switch (see

Figure 86 "Signaling Server

indicators and power switch" (page 238)

). Notice that the green

LED power indicator is lit.

Nortel Communication Server 1000

Branch Office Installation and Commissioning

NN43001-314

01.02

Standard

Release 5.0

20 June 2007