Nortel Networks NN43001-314 User Manual

Page 217

Advertising
background image

IP Phone passwords and parameters

217

1

Configure the length of the password, SCPL, to be of non-zero
length in LD 15.

LD 15 Configure the SCPW length in the Customer Data Block.

Prompt

Response

Description

REQ:

CHG

Change existing data.

TYPE:

FFC

Flexible Feature Code

SCPL

0-8

Length of SCPW, minimum recommended is 4 digits

2

Assign the Automatic Set Relocation security code.

LD 15 Assign Automatic Set Relocation security code.

Prompt

Response

Description

REQ:

CHG

Change existing data.

TYPE:

FTR

Customer Features and options

CUST

Customer number

0-99

Range for Large System and CS 1000E system

0-31

Range for Small System and Media Gateway 1000B

SRCD

(0000)-9999

Automatic Set Relocation security code X removes
security code

3

Configure the Flexible Feature Code in LD 57 to enable Station
Control Password Change (SCPC) and Set-Based Removal if
desired.

LD 57 Enable password change and set removal features.

Prompt

Response

Description

REQ

NEW

Add new data.

TYPE

FFC

Flexible Feature Code

CUST

xx

Customer number as defined in LD 15

FFCT

YES

Flexible Feature Confirmation Tone

CODE

AREM

Automatic Set Removal

- AREM

xxxx

Code to invoke Automatic Set Removal

CODE

SCPC

Station Control Password Change

- SCPC

xxxx

Code to invoke password change

4

The SCPW itself is configured during IP Phone configuration, either
using TM 3.1 (see

"MG 1000B IP Phone configuration using TM

Nortel Communication Server 1000

Branch Office Installation and Commissioning

NN43001-314

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2007, Nortel Networks

.