Connecting to the Host’s RS-232C Port

Section 5-1

Note

A Serial Communications Board cannot be installed.

Usable Cables with Attached Connectors:
For host link, 1:1 NT Link, or 1:N NT Link (+5 V power supplied from PLC)

XW2Z-070T-1(9-pin to 9-pin, 0.7 m)
XW2Z-200T-1(9-pin to 9-pin, 2 m)

Since the CS1G/H, CQM1H, and C200HX/HG/HE(-Z)E have a +5 V output,
no external power supply is required for the NT-AL001.

5-1-4

Recommended Connectors, Cables, and Crimp Terminals

Connectors and Cables Recommended for RS-232C

When making an RS-232C connecting cable, as far as possible use the rec-
ommended parts indicated in the table below. Some Units come supplied with
one connector and connector hood.

Check the required parts and prepare them in advance.

CJ1G-CPU44/45

CJ1G-CPU42H/43H/44H/45H

CJ1H-CPU65H/66H/67H

CJ1M-CPU11/12/13/21/22/23

CQM1H-CPU51/61

C200HE-CPU32/42(-Z)E

C200HG-CPU33/43/53/63(-Z)E

C200HX-CPU34/44/54/64(-Z)E

C200HX-CPU65–ZE/85–ZE

6

5

9

1

6

5

9

1

Shielding wire

(9-pin type)

NT-AL001 side

PLC side

(9-pin type)

Abbreviation Pin number

Pin number

Abbreviation

RS-232C
connector

Connector
hood

RS-232C
connector

Connector
hood

1

2

3

4

5

6

7

8

9

FG

SD

RD

RS

CS

+5V

SG

FG

SD

RD

RS

CS

+5V

SG

1

2

3

4

5

6

7

8

9

Name

Model

Remarks

Delivered with

Connector

XM2A-0901

9-pin type

Made by OMRON

CS/CJ-series PLCs,
C-series CQM1, C200HS,
C200HX/HG/HE(-Z)E

CVM1/CV-series CPU Units

CV500-LK201

XM2A-2501

25-pin type

Made by OMRON

C500-LK203

3G2A5-LK201-EV1

C200H-LK201-V1

DB-25P

25-pin type

Made by JAE

3G2A5-LK201-EV1