Functions of the NT631/NT631C

Section 1-2

1-2-3

Comparison between NT620S/NT620C/NT625C and NT631/
NT631C

Item

NT620S/NT620C/NT625C

NT631/NT631C

Support Tool used

NT-ZJCAT1-EV4 or NT-ZA3AT-EV2

NT-ZJCAT1-EV4

DIP switches

On rear of PT

None (software settings)

Use of Memory Unit

Not possible

Possible

RS-232C interface

Connector (9-pin) also used as port for
screen data transfer.

- Serial port A connector (also used for screen

data transfer, 9-pin)

- Serial port B connector (for host communica-

tions only, 9-pin)

RS-422A/485 interface

NT620S/NT620C: None

NT625C: Terminal block (DIP-switch
selectable between RS232C and RS-
422A/485)

Terminal block (serial port B; memory-switch
selectable between RS232C and RS-422A/485)

Replacement backlight

NT620C-CFL01 (NT620C)
NT610C-CFL02 (NT625C)

NT631C-CFL01 (for ST151; the backlight for the
NT631C-ST152

@-EV2, NT631C-ST153@-EV3,

however, cannot be replaced by the user)

NT631C-CFL02 (for ST141)

NT631/NT631C system pro-
gram data

NT620-ZS3AT-EV1/EMV1
(including system installer)

The system installer and system program data
are supplied with the Support Tool.

High-speed 1:N NT Link

Not possible

Possible

Memory
Link

System program

Exclusive use by Memory Link

Same as OMRON connection

Screen data

Shared with OMRON connection

Exclusive use by Memory Link

LCD contrast adjustment

By a control on the rear of the PT

By touch panel operation
(Possible in the NT631-ST141

@-V2 only.)

Backlight brightness adjust-
ment

Not possible

By touch panel operation
(Possible in the NT631-ST141

@-V2 only.)

Number of user-registered
screens

Maximum of 2000

Maximum of 3999

Screen data capacity

*1

(User program memory)

NT620S: 512 KB
NT620C/NT625C: 1 MB

1 MB

Numeral string data

Maximum of 1000

Maximum of 2000

Character string data

Maximum of 1000

Maximum of 2000

Bit data

256

Maximum of 1000

Mathematical tables

None

256 max.
Calculations can be executed automatically in
the PT.

Image data

Maximum of 224

Maximum of 4095

*2

Library data

Maximum of 896

Maximum of 12288

*2

Method for storing numeric
values
(numeral memory data and PT
status control area)

Fixed as BCD (binary coded decimal)

Selectable from BCD (binary coded decimal) or
binary

PT status control area size

4 words

5 words (partial change of contents)

*2

PT status notify area size

3 words

2 words (partial change of contents)

*2

Window control area size

None

9 CH

Registering continuous screen Possible

Not possible (Use a screen switchover as a sub-
stitute.)

Lamp/Touch switch labels

Fixed display (1 line only)

- Multiple lines can be displayed

- ON/OFF switching is possible

- Numeral display is possible

- Character string display is possible