Connecting to the RS-232C Port at the Host

Section 4-1

*1

One of the following Communications Boards is required: C200HW-
COM02/COM04/COM05/COM06-EV1.

*2

A CPM1-CIF01 Adapter is required.

*3

Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-
CIF01 RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to connect.

*4

A CQM1H-SCB41 Serial Communications Board is required.

*5

CPU Units of CVM1/CV-series PLCs without the suffix -EV

@ cannot be

connected.

Reference:

CS/CJ-series CPU Units cannot be connected with the 1:1 connection NT link
method. Use the 1:N connection NT link method (standard or high-speed)
instead to make the 1:1 connection. For details, refer to Using the NT Link
(1:N) Method
(page 65) or Using the High-speed NT Link (1:N) Method
(page 70).

Settings at the Host

The setting methods for each Unit are as follows.

Connecting to a C-series C200HS, C200HX/HG/HE(-Z)E, CPM1, CPM2A,
CPM2C, CQM1, CQM1H or SRM1 PLC

PLC Setup Area Settings

Write the PLC Setup area (data memory) settings directly from a Program-
ming Device (e.g. CX-Programmer) in accordance with the host model and
port.

*1

RS-232C port of the Communications Board

*2

RS-232C port of the Serial Communications Board

For details on operations relating to the PLC Setup area, refer to the manual
for the PLC which is used.

CVM1
Series

(*5)

CVM1-CPU01-EV2

CVM1-CPU11-EV2

CVM1-CPU21-EV2

CVM1

CompoBus/
S Master
Control Unit

SRM1-C02-V1

SRM1

PLC Series

CPU Units with Built-in

NT Link Function

CPU Units Connect-

able with Expansion

Communications

Board

(*1)

Connectable to

Host Model

Word #

Writing Value

Setting

RS-232C port of C200HS, C200HX/
HG/HE(-Z)E, CPM2A, CPM2C,
CQM1, CQM1H, SRM1

DM6645

4000

Use NT link
(1:1)

Port A of C200HX/HG/HE(-Z)E

(*1)

Port 1 of CQM1H

(*2)

DM6555

Port B of C200HX/HG/HE(-Z)E

(*1)

DM6550

CPM1

DM6650