Omron Programmable Terminals NT631C User Manual

Page 75

Advertising
background image

58

Connecting to the RS-232C Port at the Host

Section 4-1

When using the CQM1H’s built-in peripheral port, turn ON SW7.

Setting the Switches of a CPM2A

When using a CPM2A, the switches on the front panel must be set as shown
below in order to make the PLC Setup settings effective.

Setting the Switches of a CPM2C

When using a CPM2C, the switches on the front panel must be set as shown
below in order to make the PLC Setup settings effective.

Setting the Switches on a RS-232C Adapter

When using a CPM1-CIF01 RS-232C Adapter, set the mode switch as shown
in the following diagram.

C200HX/HG/HE(-Z)E

CQM1

CQM1H

RS-232C port communications condition setting
Set DIP SW5 to OFF to make the settings made
in PC Setup effective.

Set the Communications
switch to OFF (down
position).

• Connecting PT to peripheral port

• Connecting PT to built-in RS-232C port

SW1: OFF
SW2: ON

• Connecting PT to built-in RS-232C port

(A Programming Console is connected to the peripheral port.)

SW1: OFF
SW2: OFF

(A device that requires non-standard communications settings
is connected to the peripheral port.)

The settings for SW1 and SW2 depend upon the usage of
the peripheral port and RS-232C port.

CPM1

Set the mode setting switch to HOST (upper position).

CPM1-
CIF01

Advertising