4-3 data format, Data format – Omron Programmable Terminals NT631C User Manual

Page 55

Advertising
background image

38

Connecting a Bar Code Reader

Section 3-4

About RS/CS Control

During bar code reading, the NT631/NT631C performs RS/CS control. When
the Input Method setting of the NT631/NT631C is set to Auto, the RS signal is
turned OFF, prohibiting the next input, until the read data has been sent to the
host as notification.

Because of this, when the Auto setting is made, the next input is not possible
until the data has been sent to the host as notification.

However, when the setting is Auto and the RS/CS signals of the cable are
shorted, RS/CS control is ineffective. Consequently, data input from the bar
code reader to the NT631/NT631C is updated regardless of whether or not
the data is sent to the host as notification.

For details, refer to the instruction manual for the bar code reader used.

3-4-3

Data Format

The data format for communications when using the bar code input function of
the NT631/NT631C is shown below.

The characters which are effective as data are hexadecimal codes from 20 to
7FH, and the maximum data length is 40 bytes.

Data which does not follow the data format described above is invalidated and
discarded.

Preamble

STX

Postamble

ETX

RS/CS control

Available

Communications protocol

No-protocol mode

Transmission of number of bar code label digits

Transmission prohibited

Transmission of ID characters

Transmission prohibited

Bar code types

Multi-reading (all types can be
read)

Trigger switch setting

Automatic reading mode

Item

Possible Settings

Data

Data

Data

STX

ETX

(03

H

)

(02

H

)

Advertising
This manual is related to the following products: