5-4 clearing screen data, Clearing screen data – Omron Programmable Terminals NT631C User Manual

Page 165

Advertising
background image

148

Operations in the System Installer Mode

Section 6-5

Change the system settings by following the menu operation from the System
Installer mode menu shown below.

• If Cancel is selected, the NT631/NT631C returns to the System Installer

mode menu without changing the settings. The settings remain as they
were before the operation was started.

• If writing of the settings fails, a screen asking whether you wish to try

again is displayed.

After the settings have been written, the System Installer mode menu screen
is redisplayed.

6-5-4

Clearing Screen Data

If the screen data has been corrupted and the NT631/NT631C cannot be
started normally, use this function to clear the screen data.

Note that only the screen data is cleared (initialized), and the memory switch
settings and the display history/alarm history record data are retained.

Reference:

• When this function is used, all of the screen data contents registered in

the NT631/NT631C up to that point are cleared. Check that the created
screens are backed up at the Support Tool before using it.

• The screen data can also be cleared from the System Menu (page 135).

Select Change System Settings.

Select OK.

Select Display System Menu or Screen
Memory Protect.
Each time either of these items is
selected, the setting switches from
Disabled to Enabled or vice versa.

The settings are written to the
NT631/NT631C while the screen is
displayed.