6-20 LAN-to-LAN Routing

The second method is to configure each modem to dial a differ-
ent stored number. This is done using the modem’s AT&Z
command. You can send this command to the modem from the
NETServer’s command line by typing the following:

set s<port #> at “AT &Z<slot #>=<phone number>\r”

<slot#> is the position (0-9) in the modem’s non volatile memory
(each modem stores up to ten numbers).

Repeat for each modem in the dial group. Note that a different
phone number must be stored for each modem, but <slot#>
must be the same for all modems.

Step 4 - Create a Dial Script

Dial scripts tell the NETServer how to dial and, if necessary, log
into a remote location. Each line of a dial script contains a send
string and a reply string. The NETServer issues the send string
to the port making the connection and then waits until it re-
ceives the reply string.

The send strings should end with a \r (carriage return) character.
reply strings are case-sensitive. Also, the send and reply options
must be enclosed in quotes (“ ”).

set location <location> script <line #> “<send>\r” “<reply>

To dial 555-1000 and wait for a CONNECT message from the
modem:

set location Chicago script 1 “atdt5551000\r” “CONNECT”

Note:

Waiting for a CONNECT message from the internal

modem requires that the modem be configured to respond with
verbal result codes (add the AT commands Q0V1 to the init
string of each modem). If the modem is not configured to send
verbal result codes, the NETServer will wait indefinitely for a
message that does not arrive.

Alternatively, try putting the remote systems “login:” prompt in
the expect string instead of the connect message.