A5-11 – Yokogawa digitalYEWFLO (DY-FF) User Manual

Page 107

Advertising
background image

Index Parameter Name Initial Value

Write

Mode

Defi nition

29 INTEG_OPTS

0x0004

AUTO

Specifi es an integration optional function.

bit

Option Name

Description

0

Input 1 accumulate Selects Rate or Accum input of IN_1.

1

Input 2 accumulate Selects Rate or Accum input of IN_2.

2

Flow forward

Integrates forward fl ow (interprets reverse fl ow as zero).*

3

Flow reverse

Integrates reverse fl ow (interprets forward fl ow as zero).*

4

Use uncertain

Uses an input value of IN_1 or IN_2 whose status is “Uncertain”
regarding it as a value of “Good.”

5

Use bad

Uses an input value of IN_1 or IN_2 whose status is “Bad”
regarding it as a value of “Good.”

6

Carry

Carries over an excess exceeding the threshold at reset to the
next integration. (Note that this does not apply to UP_AUTO or
DN_AUTO.)

7

Add zero if bad

Interprets an increment as zero if the status of the increment is
“Bad.”

8

Confi rm reset

After a reset, rejects the next reset until “Confi rm” is set to
RESET_CONFIRM.

9

Generate reset
event

Generates an alert event at reset.

10~15 Reserved

* If both forward and reverse fl ows are enabled or disabled, both forward and reverse fl ows

are integrated.

30 CLOCK_PER

86400.0[sec]

AUTO

Specify the period at which a periodic reset is made.

31 PRE_TRIP

100000.0

AUTO

Set an allowance applied before an integrated value exceeds the setpoint.

32 N_RESET

0.0

Indicates the number of resets in the range of 0 to 999999.

33 PCT_INCL

0.0[%]

The ratio of “the integrated values of the absolute values of the increments whose
status is Good” to the “integrated values of the absolute values of the increments
irrelevant to the status” (Equation)

34 GOOD_LIM

0.0[%]

AUTO

The threshold value of the ratio of “the integrated values of the increments whose
status is Good” to all integrated values in which the status of OUT is “Good”

35 UNCERT_LIM

0.0[%]

AUTO

The threshold value of the ratio of “the integrated values of the increments
whose status is Good” to all the integrated values in which the status of OUT is
“Uncertain”

36 OP_CMD_INT

0

AUTO

Operator command that resets integrated values

37 OUTAGE_LIM

0.0

AUTO

Maximum time for which values can be retained in the event of power failure.
It does not effect the block operation.

38

RESET_
CONFIRM

0 AUTO

Reset confi rmation input, which is enabled when the Confi rm reset option of
INTEG_OPTS is chosen

39 UPDATE_EVT

1 AUTO

Indicates event information if an update event occurs.

1 —
0 —
0 —
0 —

40 BLOCK_ALM

1 AUTO

Indicates alarm information if a block alarm occurs.

1 —
0 —
0 —
0 —

41 ACCUM_TOTAL

0.0

Accumulated integrated values (no extension parameter is reset)

<APPENDIX 5. INTEGRATOR (IT) BLOCK>