<10. EXPLOSION PROTECTED TYPE INSTRUMENT>

10-11

IM 01F06F00-01EN

10.3 IECEx

WARNING

• Only trained persons use this instrument in

industrial locations.

• Electrostatic charge may cause an explosion

hazard.

Avoid any actions that cause the generation

of electrostatic charge, such as rubbing with
a dry cloth on coating face of product.

Technical

Data

• Flameproof
Applicable Standard : IEC60079-0: 2007-10,

IEC60079-1: 2007-04

Certifi cate : IECEx DEK 11.0077X
Type of Protection:
Ex d IIC T6…T1 Gb (Integral Type Vortex

Flowmeter and Remote Type Vortex Flow
Detector)

Ex d IIC T6 Gb (Remote Type Vortex Flow

Convertor)

Specifi cation of Protection:

Process

Temperature:

(Integral Type Vortex
Flowmeter and Remote
Type Vortex Flow
Detector)

Temperature Class

Process Temperature

T6

-29°C to +80°C

T5

-29°C to +100°C

T4

-29°C to +135°C

T3

-29°C to +200°C

T2

-29°C to +300°C

T1

-29°C to +450°C

*1 Note: Use /HT version above 250°C

Temperature Class: T6 (Remote Type Vortex Flow
Convertor)
Ambient

Temp.:

–29 to +60°C (Integral Type Vortex

Flowmeter and Remote Type Vortex Flow
Detector)

–40 to +60°C (Remote Type Vortex Flow

Convertor without indicator)

–30 to +60°C (Remote Type Vortex Flow

Convertor with indicator)

Power Supply: 9 to 32Vdc max.
Special Fastener: Class A2-50 or more

Special conditions for safe use
1. For process temperatures above 250°C the fl ow

meters of the /HT version must be used.

Installation

WARNING

• All wiring shall comply with local installation

requirements and local electrical code.

• Use the suitable heat-resisting cables (over

90°C) for the digitalYEWFLO Model DY
Series Vortex Flowmeter when the ambient
temperature exceeds 60°C and/or the
process temperature exceeds 200°C.

• The cable entry devices shall be certifi ed in

type of protection fl ame proof enclosure “d”
and suitable for the conditions of use and
correctly installed.

• Unused apertures shall be closed with

certifi ed blanking elements in type of
protection fl ame proof enclose “d”.

The grounding terminals are located on the inside
and outside of the terminal area.
Connect the cable to grounding terminal in
accordance with wiring procedure (1) or (2).

Case

Cable

Screw

(1) Internal grounding terminal

(2) External grounding terminal

Washer

Washer

Cable

Clamp

Screw

F1006.ai

Figure 10.2 Wiring Procedure for Grounding

Terminals