<APPENDIX 9. DD MENU>

A9-2

IM 01F06F00-01EN

(2) Transducer Block

Transducer Block (Top menu)

Block Info
|

Block Tag

|

Tag Description

|

Strategy

|

Alert Key

|

Transducer Directory

|

Transducer Type

Block Mode
|

Target

|

Actual

|

Permitted

|

Normal

Dynamic Variables
|

Primary Value

|

|

Value

|

|

Status

|

Secondary Value

|

|

Status

|

|

Value

|

|

Secondary Value Unit

|

Tertiary Value

|

|

Status

|

|

Value

|

|

Tertiary Value Unit

|

Volumetric Flow

|

Status

|

Value

|

Volumetric Flow Unit

Configuration/Calibration
|

Block Mode

|

|

Target

|

|

Actual

|

|

Permitted

|

|

Normal

|

Setup Wizard

|

General

|

|

Model

|

|

Sensor Info

|

|

|

Sensor Type

|

|

|

Sensor Status

|

|

|

Sensor Serial Number

|

|

|

Sensor Range

EU at 100
EU at 0

|

|

|

|

|

|

|

|

|

|

|

|

Units Index

|

|

|

|

Decimal

|

|

|

Linearization Type

|

|

|

Primary Value Type

|

|

Primary Value Range

|

|

|

EU at 100

|

|

|

EU at 0

|

|

|

Units Index

|

|

|

Decimal

|

|

Transducer Calibration Info

|

|

|

Sensor Calibration Method

|

|

|

Calibration Highest Point

|

|

|

Calibration Lowest Point

|

|

|

Calibration Minimum Span

|

|

|

Calibration Unit

|

|

|

Sensor Calibration Location

|

|

|

Sensor Calibration Date

|

|

|

Sensor Calibration Who

|

Fluid Condition

|

|

Fluid Type

|

|

|

Sensor Status

|

|

|

Fluid Type

|

|

|

Thermometer Function

|

|

Temperature Set

|

|

|

Temparature Unit

|

|

|

Process Temparature

|

|

|

Base Temparature

|

|

Density Set

|

|

|

Density Unit

|

|

|

Process Density

|

|

|

Base Density

|

|

Pressure Set

|

|

|

Pressure Unit

|

|

|

Process Pressure

|

|

|

Base Pressure

|

|

Other Condition set

|

|

Primary Value Filter Time

|

|

Deviation

|

|

First Temperature Coef.

|

|

Second Temperature Coef.

|

|

Secondary Value Filter Time

|

|

Cable Length

|

Characterize Meter

|

|

Size Select

|

|

|

|

Body Type

|

|

Vortex Sensor Type

|

|

K-Factor Unit

|

|

K-Factor Value

|

Display Set

|

|

Upper Display Mode

|

|

Lower Display Mode

|

|

Display Cycle

|

Adjust

|

|

Reynolds Adjust

|

|

Viscosity Value

|

|

Flow Adjust

|

|

User Adjust

|

|

Gas Expansion Fact

|

Maintenance

|

|

Low Cut Flow

|

|

Trigger Level

|

|

Noise Balance Mode

|

|

Noise Ratio

|

|

Noise Balance Wizard

|

|

Signal Level

|

|

Sensor Error Record

|

|

Flow Velocity

|

|

Span Velocity

|

|

Vortex Frequency

|

|

Span Frequency

|

|

Fluid Density

|

Limit Switch 1 Set

|

|

Limit Switch 1 Value D

|

|

|

Status

|

|

|

Value

|

|

Limsw 1 Target

|

|

Limsw 1 Setpoint

|

|

Limsw 1 Act Direction

|

|

Limsw 1 Hysteresis

|

|

Limsw 1 Unit

|

Limit Switch 2 Set

|

Limit Switch 2 Value D

|

|

Status

|

|

Value

|

Limsw 2 Target

|

Limsw 2 Setpoint

|

Limsw 2 Act Direction

|

Limsw 2 Hysteresis

|

Limsw 2 Unit

Diagnostics/Alerts
|

Block Error

|

Transducer Error

|

Alarm Perform

|

Block Alarm

|

|

Unacknowledged

|

|

Alarm State

|

|

Time Stamp

|

|

Subcode

|

|

Value

|

Alarm Summary

|

|

Current

|

|

Unacknowledged

|

|

Unreported

|

|

Disabled

|

Update Event

|

Unacknowledged

|

Update State

|

Time Stamp

|

Static Rev

|

Relative Index

Query Device

TB Profile Parameters
TB Original Parameters(part1)
TB Original Parameters(part2)
TB Original Parameters(part3)
TB Original Parameters(part4)
TB Service Parameters

FA0902.ai

Note: Parameter name may differ according to a tool or host.