4 csa – Yokogawa digitalYEWFLO (DY-FF) User Manual

Page 62

Advertising
background image

<10. EXPLOSION PROTECTED TYPE INSTRUMENT>

10-13

IM 01F06F00-01EN

10.4 CSA

Technical

Data

• Explosion Proof
Applicable Standard: C22.1-98, C22.2 No.0-M1991,

C22.2 No.0.4-04, C22.2
No.0.5-1982, C22.2 No. 25-
1966, C22.2 No. 30-M1986,
C22.2 No. 94-M1991, C22.2
No. 142-M1987, C22.2 No.
61010-1-04, ANSI/ISA-
12.27.01-2003

Certifi cate

: 1166201

Type of Protection: Explosion proof for Class I, B, C

and D; Class II, Groups E, F and
G; Class III. For Class I, Division
2 location:

“FACTORY SEALED, CONDUIT SEAL NOT

REQUIRED.”

Enclosure : Type 4X
(Integral Type Vortex Flowmeter and Remote Type
Vortex Flow Detector)

Temperature Code

Ambient

Temperature

Process

Temperature

T6

60°C

≤85°C

T5

60°C

≤100°C

T4

60°C

≤135°C

T3

60°C

≤200°C

T2

60°C

≤300°C

T1

60°C

≤450°C

Temperature Code: T6 (Remote Type Vortex Flow

Converter)

Ambient Temperature: -29 to +60°C (Integral Type

Vortex Flowmeter and
Remote Type Vortex Flow
Detector)
-40 to +60°C (Remote Type
Vortex Flow Converter)

Power Supply: 9 to 32Vdc (Integral Type Vortex

Flowmeter and Remote
Type Vortex Flow Converter)

Output Signal (Remote Type Vortex Flow Detector):

Output Signal; 30Vp-p,
100

μAp-p

Input/Output signal (Remote Type Vortex Flow

Converter):

Input Signal; 30Vp-p,
100

μAp-p

Electrical Connection: ANSI 1/2 NPT female

(Special)

Dual Seal (Option /CF11)

Dual Seal:
Certifi ed by CSA to the requirement of ANSI/ISA

12.27.01

No additional sealing required.
Primary seal failure annunciation: at the O-ring

seal portion between shedder bar and amplifi er
housing.

Advertising