Explosion protected type instrument, 1 atex, Explosion protected type instrument -1 – Yokogawa digitalYEWFLO (DY-FF) User Manual

Page 50: Warning, 1 atex warning

Advertising
background image

<10. EXPLOSION PROTECTED TYPE INSTRUMENT>

10-1

IM 01F06F00-01EN

10. EXPLOSION PROTECTED TYPE

INSTRUMENT

In this section, further requirements and differences
for explosion proof type instrument are described
except JIS Flame proof. For explosion proof type
instrument, the description in this chapter is prior to
other description in this Instruction Manual.

WARNING

• Only trained persons use this instrument in

industrial locations.

10.1 ATEX

WARNING

• Only trained persons use this instrument in

industrial locations.

• Electrostatic charge may cause an explosion

hazard.

Avoid any actions that cause the generation

of electrostatic charge, such as rubbing with
a dry cloth on coating face of product.

Technical

Data

• Flameproof
Applicable Standard : EN 60079-0: 2009,

EN 60079-1: 2007

Certifi cate : DEKRA 11ATEX0212X
Type of Protection:
Group:

II

Category: 2 G
Ex d IIC T6…T1 Gb (Integral Type Vortex

Flowmeter and Remote Type Vortex Flow
Detector)

Ex d IIC T6 Gb (Remote Type Vortex Flow

Convertor)

Specifi cation of Protection:
Process Temperature: (Integral Type Vortex

Flowmeter and Remote
Type Vortex Flow
Detector)

Temperature Class

Process Temperature

T6

-29°C to +80°C

T5

-29°C to +100°C

T4

-29°C to +135°C

T3

-29°C to +200°C

T2

-29°C to +300°C

T1

-29°C to +450°C

*1 Note: Use /HT version above 250°C

Temperature Class: T6 (Remote Type Vortex Flow

Convertor)

Ambient

Temp.:

–29 to +60°C (Integral Type Vortex

Flowmeter and Remote Type Vortex Flow
Detector)

–40 to +60°C (Remote Type Vortex Flow

Convertor without indicator)

–30 to +60°C (Remote Type Vortex Flow

Convertor with indicator)

Power Supply: 9 to 32Vdc max.
Special Fastener: Class A2-50 or more

• Intrinsically Safe
Applicable Standard: EN 50014: 1997 +A1, +A2,

EN 50020: 2002,

EN 60079-27: 2006,

EN 50284: 1999

Certifi cate:

KEMA 03ATEX1136X

Type of Protection: EEx ia IIB/IIC T4...T1 (Integral

Type Vortex Flowmeter and
Remote Type Vortex Flow
Detector)

EEx ia IIB/IIC T4 (Remote
Type Vortex Flow Converter)

Group: II
Category: 1 G
Tamb: –29 to +60°C (Integral Type Vortex

Flowmeter)

–29 to +80°C (Remote Type Vortex Flow
Detector)

–40 to +60°C (Remote Type Vortex Flow
Converter)

Advertising