1.2 MW100 Operation Guide

The figure below shows the general flow of operation when the MW100 is installed
initially.

Wire the input/

output modules

Operations on the MW100

Connect

communication

cables

Connect the power

cord

Set up

communication

Configure the

system

Enter data

acquisition

conditions

Set measurement

conditions

MATH settings

FTP and e-mail

settings

Instal the MW100

and attaching the

main module

See the Installation

and Connection

Guide

(IM MX100-72E).

Transmission

output settings

Alarm settings

Event settings

Search for all connected MW100s and

configure network parameters such as

the MW100s’ IP addresses.

Select the acquisition interval to be

used, select the recording interval,

set recording start/stop conditions, etc.

Input channel settings, input type,

measurement range, measurement

span, etc.

Analog/PWM output settings

Event/action settings

Settings for the FTP server, mail server,

and other network utilities

Measured data and alarm display

settings while online

Data display and analysis using MW100

Viewer Software.

See the MW100 Viewer Software User’s

Manual (IM MW180-01E).

While online you can start

measurement, computation, and

recording from a PC

Starting measurement,

computation, and recording

Alarm level and type settings

Alarm output, manual DO, Fail output,

and error output settings

MW100 system configuration, date/time

setting, CF card setup

Section 3.3

Section 3.4

Section 3.5

Section 3.6

Section 3.7

Digital output

settings

MATH channel settings, entry of

expressions, etc.

Section 3.8

Section 3.9

Section 3.14

Display and

check data

Monitor data and

alarms

Section 3.16

Section 3.10 and 3.11

Report settings

Set up creation of hourly, daily, weekly,

or monthly reports

Section 3.12

Section 3.2

Section 2.5

Turn ON the power

switch

Section 2.5

Section 2.6 to 2.8

Section 2.4

Section 2.2 and 2.3

Start measurement,

computation,

or recording

Section 3.13

Section X.X indicates the referred

sections in this manual.

While online you can stop

measurement, computation, and

recording from a PC

Stopping measurement,

computation, and recording

Stop measurement,

computation,

or recording

Section 3.13