TLOG Time Scale
You can select the sum scale for the TLOG.SUM computation.
Integration Units
Notation Explanation
No time scale
Off
Σ (data)
*1
Every second
/sec
Σ (data)/(Number of times of computing per second.)
Every minute
/min
Σ (data)/(Number of times of computing per minute.)
Every hour
/hour
Σ (data)/(Number of times of computing per hour.)
Every day
*2
/day
Σ (data)/(Number of times of computing per day.)
*1 Integration of data every MATH interval
*2 Firmware version R3.03 or later
1.15 MATH Function (/M1 Option)