Brocade Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide (Supporting R05.6.00) User Manual
Page 445

Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide
421
53-1003031-02
Displaying LDP information
2
The following example displays a VC type mismatch where two VC FEC_CBs are displayed for the
same VC ID of 1000. In the example, the user can see that one VC type displays 5, and the other VC
type displays 11. The two VC FEC_CBs are not associated with each other in any way. The VC type
mismatch causes the VC label to display a Retained state instead of an Installed state.
Brocade# show mpls ldp fec vc 1000
FEC_CB: 0x29391234, idx: 5, type: 128, pend_notif: None
State: retained, Ingr: Yes, Egr: Yes, UM Dist. done: No
VC-Id: 1000, vc-type: 5, grp-id: 0, local-mtu: N/A, remote-mtu: 1500
Downstream mappings:
Local LDP ID Peer LDP ID Label State CB
10.128.128.28:0 10.125.125.1:0 983040 Retained 0x29391140(-1)
FEC_CB: 0x29391510, idx: 4, type: 128, pend_notif: None
State: current, Ingr: Yes, Egr: Yes, UM Dist. done: Yes
VC-Id: 1000, vc-type: 11, grp-id: 0
Local-mtu: 1500, remote-mtu: N/A, MTU enforcement: enabled
Upstream mappings:
Local LDP ID Peer LDP ID Label CB
10.128.128.28:0 10.125.125.1:0 983041 0x2939141c(-1)