GBS-1000 Series User Manual

100

Example

Normal

Peak Detect

Average (2 times)

Average (256 times)

Peak detect effect
using probe
comp. waveform

1. One of the probe

compensation waveforms
can demonstrate peak
detection mode. Connect the
probe to the probe
compensation output.

2. Press the Utility key.

Utility

3. Press F5 (More) twice.

More

F 5

x2

4. Press F1 (Probe Comp.

Menu)

ProbeComp

Menu

F 1

5. Press F1 (Wave Type) and

select the

waveform.

Wave Type

F 1

6. Press the Auto Set key. GBS-

1000 positions the
waveform in the center of
the display.

Auto Set

7. Press the Acquire key.