GW Instek GBS-1000 Series User Manual User Manual
Page 179

APPENDIX
179
Trigger
Sources
CH1, CH2, CH3, CH4, Line
Modes
Auto-Level, Auto, Normal, Single, TV,
Edge, Pulse Width
Coupling
AC, DC, LFrej, HFrej, Noise rej
Sensitivity
DC~25MHz: Approx. 0.5div or 5mV
25MHz~max: Approx. 1div or 10mV
Horizontal
Range
1ns/div~10s/div, 1-2-5 increment
Roll mode: 250ms/div ~ 10s/div
Modes
Main, Window, Window Zoom, Roll, Scan,
X-Y
Accuracy
±0.01%
Pre-Trigger
20 div maximum
Post-Trigger
1000 div
X-Y Mode
X-Axis Input
Channel 1
Y-Axis Input
Channel 2, 3, 4
Phase Shift
±3° at 100kHz
Signal Acquisition Real-Time
1G Sa/s maximum
Equivalent
25G Sa/s maximum
Vertical
Resolution
8 bits
Record Length 25K Dots Maximum
Acquisition
Normal, Peak Detect, Average
Peak Detection 10ns
Average
2, 4, 8, 16, 32, 64, 128, 256
Cursors and
Measurement
Voltage
Vpp, Vamp, Vavg, Vrms, Vhi, Vlo, Vmax,
Vmin, Rise Preshoot/ Overshoot, Fall
Preshoot/ Overshoot
Time
Freq, Period, Rise Time, Fall Time, Positive
Width, Negative Width, Duty Cycle
Delay
FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF
Cursors
Voltage difference (ΔV) and
Time difference (ΔT) between cursors
Auto Counter
Resolution: 6 digits
Accuracy: ±2%
Signal source: All available trigger source
except the Video trigger
Control Panel
Function
Auto Set
Automatically adjust Vertical Volt/div,
Horizontal Time/div, and Trigger level
Save Setup
Internal memory: 20 sets
USB Flash drive: unlimited
Save Waveform Internal memory: 20 sets
USB Flash drive: unlimited
Save display
image
USB Flash drive: unlimited