CONFIGURATION

125

Single

GBS-1000 acquires a
waveform once when a
trigger event occurs, then
stops acquiring. Press the
Run/Stop key to acquire a
waveform again.

Run/Stop

Auto level

When turning this function ON, GBS-1000
automatically adjusts the trigger level to the center
amplitude of the waveform.

Holdoff

The holdoff function defines the waiting period
before GBS-1000 starts triggering again after a
trigger point. The Holdoff function ensures a
stable display.

Video standard
(video trigger)

NTSC

National Television System Committee

PAL

Phase Alternative by Line

SECAM

SEquential Couleur A Memoire

Sync polarity
(video trigger)

Positive polarity

Negative polarity

Video line
(video trigger)

Selects the trigger point in the video signal.

field

1 or 2

line

1~263 for NTSC, 1~313 for PAL/SECAM

Pulse condition
(pulse trigger)

Sets the pulse width (20ns ~ 10s) and the triggering
condition.

>

Longer than =

Equal to

<

Shorter than ≠

Not equal to

Trigger slope

Triggers on the rising edge.

Triggers on the falling edge.