Go-nogo test, Overview, E78) – GW Instek GBS-1000 Series User Manual User Manual

Page 78: Ge78)

Advertising
background image

GBS-1000 Series User Manual

78

Go-NoGo Test

Overview

Background

The Go-NoGo test checks if a waveform fits inside
a user-specified maximum and minimum
amplitude boundary (template). The test result is
communicated in three ways: the display (menu
contents), buzzer sound, and pulse signal output
from the rear panel terminal.

Test parameters item

default setting setup details

Buzzer sound when
the test fails (NoGo)

Off

page79

NoGo criteria: in or
out of the boundary

Out

page79

Test signal

Channel 1

page80

Test continue or stop
when NoGo occurs

Stop

page80

Boundary (template)
– select minimum and
maximum as separate
waveforms or create
both boundaries from
a single waveform

Min/Max
separately

page81

Default setting

To recall the default setting,
press the Save/Recall key, then
press F1 (Default Setup). See
page49 for details.

Save/Recall

Default

Setup

F 1

Advertising