There are two FC-AL I/O modules in each FCDM. These modules are the interface between the
FCDM elements and the host controller. They route data to and from the drives using loop A and
loop B.

Location in OSM Tree: System > Group > FCDM Collection > FCDM > FC-AL I/O Module

Example: FC-AL I/O Module (111.211.1.93)

Attributes

FC-AL I/O Module

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

LED State

Indicates whether or not the FC-AL I/O Modules (amber) fault LED is blinking.

Value: Blinking or Off

Type

The vendor hardware type.

Logical

Device State

The state of the component as known to the operating system on the
server.

Values

Vendor Hardware Revision

A code that identifies the generation of the component provided by its
supplier.

Device Connection

Configured
Controller Location

The location of the configured FCSA connected to the FC-AL I/O Module.

Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1

Fibre Channel
Controller

The number that identifies the FCSA FSAC connected to the FC-AL I/O
Module.

Example: FCSA FSAC (111.2.1.1)

Actions

Blink LED Off

Turns off the blinking of the FC-AL I/O Modules (amber) fault LED.

SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED OFF

Blink LED On