Power supply (fcdm), Attributes, Actions – HP NonStop G-Series User Manual

Page 173: Power supplies

Advertising
background image

Power Supply (FCDM)

Attributes

Actions

Subcomponent of a

FCDM

. There are two power supplies in each FCDM.

Location in OSM Tree: System > Group > FCDM Collection > FCDM > Power Supply

Example: Power Supply (111.211.1.95)

Attributes

Power Supply

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

LED State

Indicates whether or not the power supplys (amber) fault LED is blinking.

Value: Blinking or Off

Type

The vendor hardware type.

Logical

AC Power State

Whether the power source is On or Off.

Device State

The state of the component as known to the operating system on the
server.

Values

Vendor Hardware Revision

A code that identifies the generation of the component provided by its
supplier.

Actions

Blink LED Off

Turns off the blinking of the power supplys (amber) fault LED.

SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED OFF

Blink LED On

Causes the power supplys (amber) fault LED to blink on and off.

SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED ON