HP NonStop G-Series User Manual

Page 272

Advertising
background image

to support node numbers 17 through 24. (The remaining star topology should
already use node numbers 1 through 8.)

Note: Changing the configuration tag requires a hard reset of the switches, resulting

in a temporary disruption of ServerNet connectivity. After the configuration
tags match on respective X and Y switches, the connectivity is repaired.

Perform the Update Topology action on each cluster. When prompted, click the Disable
Cluster Alarms button. No alarms related to connectivity (that would otherwise be dialed
out on multiple nodes) are dialed out for two hours unless you perform the Rediscover
action. Other types of alarms, such as hardware failures, are still dialed out.

8.

Disconnect any existing X-fabric cables between the cluster switches. (If you are
updating from a star topology, there are no existing cables between switches.)

9.

Connect all the cables between the X-fabric switches to support the new topology. The
new switch port connections will differ from the original cluster. See

Cable Connections

Between Star Groups

. For more information on connecting cables refer to the ServerNet

Cluster Manual.

10.

Use OSM to monitor the connectivity on the X fabric for all the nodes and switches.
Connectivity on the X fabric should be restored over time. Confirm that the original
nodes of the cluster are visible. If necessary, resolve any connectivity problems by
following the repair actions.

11.

Disconnect any existing Y-fabric cables between the cluster switches. (If you are
updating from a star topology, there are no existing cables between switches.)

12.

Connect all the cables between the Y-fabric switches to support the new topology. The
new switch port connections will differ from the original cluster. See

Cable Connections

Between Star Groups

. For more information on connecting cables, refer to the ServerNet

Cluster Manual.

13.

Use OSM to monitor the connectivity on the Y fabric for all the nodes and switches.
Connectivity on the Y fabric should be restored over time. Confirm that the nodes from
the original clusters are visible.

14.

If any nodes are not visible to the cluster, perform the Add Node to ServerNet Cluster
action on the nodes that are not visible to the cluster.

15.

If there are no connectivity problems, perform the Rediscover action on the ServerNet
Cluster resource. OSM is now configured to dial out alarms.

16.

If you need to add new nodes to the cluster, use the

Add Node to ServerNet Cluster

action. This

action launches a guided procedure with online help to assist you.

If you need to move any nodes within the cluster, see the information on moving a node in the
ServerNet Cluster Manual.