Pmf2 (processor multifunction 2), Attributes, Pmf2 – HP NonStop G-Series User Manual

Page 164

Advertising
background image

Storage ASIC Initialization Test

Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.

This action is triggered automatically when a new CRU is inserted while OSM is running or when an
(SCF) STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.

Test Verify

Performs basic tests on the CRU. You can perform this action when the CRU is online.

PMF2 (Processor Multifunction 2)

Attributes

Actions

Each processor multifunction 2 (PMF2) CRU in a NonStop server contains these components:

A processor and memory board (PMB), which contains a

processor

A

service processor (SP)

Two internal

SCSI controllers

One external

SSAC

And for PMF2s in Group 1 only, an

MIOE

(Ethernet controller) to provide connectivity

between the service processor and the dedicated service LAN (for OSM).

Slot Location: PMF2 CRUs are located in slots 50 and 55 of a processor enclosure (service side).

Example: PMF2 (1.2.50)

Attributes

PMF2

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Power State

Whether the component is powered on.

Values

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.