Attributes, Actions – HP NonStop G-Series User Manual

Page 189

Advertising
background image

Attributes

SNDA

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Manufacturer

Identifies the manufacturer of the component.

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Power State

Whether the component is powered on.

Values

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Storage ASIC

Initialization State

The status of the storage ASIC in the CRU.

Values: Initialized, Not Initialized, Unknown

Actions

Replace

Launches the Replace SNDA guided procedure, which provides step-by-step instructions for
replacing the ServerNet/DA CRU.

Storage ASIC Initialization Test

Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.

This action is triggered automatically when a new CRU is inserted while OSM is running or when an
SCF STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.

Test Verify

Performs basic tests on the CRU. You can perform this action when the CRU is online.