Diagnostic Data Collection Volume

Indicates the volume in which automatic or manual data
collection will take place. This volume is assigned by
using the

Set Data Collection Volume

action.

Days to Persist Collected Diagnostic
Data

Indicates the number of days that collected hardware
failure data (collected either automatically or by the

Collect Diagnostic Data

action) is retained on the system

before being deleted.

Incident Report Configuration

Problem Incident Report Creation State

Indicates whether or not OSM's ability to create Problem
Incident Reports has been suppressed. This suppression is
accomplished by the

Suppress Problem Incident Report

Creation

action and is desirable to stop dial-out of known

problems, such as those that may occur during CRU
replacements.

Values: Suppressed, Unsuppressed

Reason for Suppression

Why the creation ability was suppressed, displayed as free
form text.

This attribute is shown only if the Problem Incident Report
Creation State value is Suppressed.

Time of Suppression

The date and time the creation ability was suppressed.

This attribute is shown only if the Problem Incident Report
Creation State value is Suppressed.

Duration of Suppression

How long the suppression will last (in minutes). The
default value is 40 minutes. You can extend he time using
the

Extend Problem Incident Report Suppression Time

action.

This attribute is shown only if the Problem Incident Report
Creation State value is Suppressed.

Actions

Add Node to ServerNet Cluster

Launches a guided procedure that adds the local system to a ServerNet Cluster. This procedure is
also used to configure or display information for Expand-over-ServerNet line handlers.

Collect Diagnostic Data

This action collects diagnostic data for your system. Upon performing the action, you are prompted
to specify date and time parameters. Based on the date and time specified: