the ServerNet/FX or ServerNet/FX2 adapter.

Dump Controller

Writes the data from the memory of the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable
unit (FRU) to the file $SYSTEM.ZSERVICE.ZFOXDUMP.

The ServerNet/FX FRU must be in the Stopped state to perform this action.

External Loopback Test

Performs the external loopback firmware diagnostic test.

Before running this test, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2
adapter field-replaceable unit (FRU) in the Stopped state.

Firmware Update

Updates the firmware for a ServerNet/FX adapter (FXSA) or ServerNet/FX 2 adapter (FX2SA).

Responsive Test

Verifies that the component is installed and responding.

Set FOX Cluster Number

Sets the node to which the ServerNet/FX or ServerNet/FX2 adapter FRU is connected.

Set Left Transmitter Power Level

Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.

High LED power is suitable for distances of 2 km through 4 km.

Low LED power is suitable for distances of less than 2 km.

Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or
ServerNet/FX 2 adapter FRU in the Stopped state. The current power level is indicated by the

Left

Transmitter Power Level

attribute.

Set Right Transmitter Power Level

Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.

High LED power is suitable for distances of 2 km through 4 km.

Low LED power is suitable for distances of less than 2 km.

Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or
ServerNet/FX 2 adapter FRU in the Stopped state. The current power level is indicated by the

Right

Transmitter Power Level

attribute.