Actions, Node port, and the, Responsive test – HP NonStop G-Series User Manual

Page 238: For the 6780 switch module

Advertising
background image

Locator

User-assigned text, that can be used to help identify the
module. The text is assigned by using the Set Locator action.

Example: Switch Group On Right in 1206

Numeric Selector Setting Used
by Firmware

The 4-digit numeric selector setting that is currently used by
the firmware.

Example: 9621

Temperature

Current Value

The current temperature, in degrees Celsius (°C), inside the
enclosure of the module.

Normal Maximum Value

The maximum acceptable air intake temperature is 65 degrees
Celsius. If the temperature rises above 65 degrees, an alarm is
generated.

Actions

Blink All LEDs Off

Turns off the blinking of the fault LEDs on the switch logic board, PICs, power supplies and
fans.

SCF Equivalent: ALTER SWITCH, BLINK NONE

Blink All LEDs On

Causes the fault LEDs on the switch logic board, PICs, power supplies, and fans to blink on and
off.

SCF Equivalent: ALTER SWITCH, BLINK ALL

Connect to UPS

Starts a new Internet Explorer window and loads the default HTTP home page provided by the
UPS vendor.

Parameter: IP Address (the IP address of the UPS)

Replace

Invokes the Replace Switch Component guided procedure that helps to replace the switch
module.

Responsive Test

Advertising