Disables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.

Parameter: Port Number

Enable ServerNet Port

Enables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.

Parameter: Port Number

Force Power Off

This action is not supported for this CRU type. See the

Prepare to Power Off

action.

Power Off

This action is not supported for this CRU type. See the

Prepare to Power Off

action.

Prepare to Power Off

Performs a precautionary check to make sure you can safely remove the CRU. This check makes
sure:

The other PMF2 CRU in this enclosure exists and is powered on

The status of the power supply for the other PMF2 CRU in this enclosure is OK

The other PMF2 CRU in this enclosure has ServerNet connectivity

The processor in the other PMF2 CRU in this enclosure has connectivity to CPU 0 or CPU 1

If the check confirms that it is safe to power off, these preparatory steps are performed:

If the SP on this PMF2 is designated as Active (Primary), resets the SP so that the peer SP
becomes primary

Disables the battery

Halts the processor on this PMF2 CRU

If the Prepare to Power Off action completes successfully, you can safely remove the CRU.

If the check fails, the Prepare to Power Off action fails, and you should perform the steps using other
OSM actions before removing the CRU.

Replace

Launches the Replace PMF guided procedure, which provides step-by-step instructions for replacing
the PMF2 CRU.