Actions – HP NonStop G-Series User Manual

Page 111

Advertising
background image

Device State

The state of the component as known to the operating system on the
server.

Values

Firmware

Version

The VPROC of the firmware currently loaded on the FRU.

Default File Name

The name of the file to be used for a firmware update.

Default File Version The version of the firmware to be used for a firmware update .

Compare State

The differences, if any, between the current and default firmware versions.

Values

Actions

Add LBU

Configures a ServerNet/FX or ServerNet/FX2 adapter as an LBU. An LBU is the SCF logical
equivalent for the adapter.

Delete LBU

Removes an LBU from the system configuration database. An LBU is the SCF logical equivalent for
the ServerNet/FX or ServerNet/FX2 adapter.

Dump Controller

Writes the data from the memory of the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable
unit (FRU) to the file $SYSTEM.ZSERVICE.ZFOXDUMP.

The ServerNet/FX FRU must be in the Stopped state to perform this action.

External Loopback Test

Performs the external loopback firmware diagnostic test.

Before running this test, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2
adapter field-replaceable unit (FRU) in the Stopped state.

Firmware Update

Updates the firmware for a ServerNet/FX adapter (FXSA) or ServerNet/FX 2 adapter (FX2SA).

Responsive Test

Verifies that the component is installed and responding.

Set FOX Cluster Number

Sets the node to which the ServerNet/FX or ServerNet/FX2 adapter FRU is connected.