Remaining Capacity Status

The remaining capacity level in the UPS batteries.

Values: Normal, Low, Depleted

If the value is Depleted, the UPS is unable to sustain the present
load if utility power is lost or absent.

Actions

Replace

Launches the Replace Switch Component guided procedure, which provides help for replacing
the component.

Common Attribute Values

Service State

This attribute appears in the list of attributes only when attention or service is required.

Value

Meaning

OK

The object is functioning properly. This value appears only in the Problem
Summary dialog box.

Attention Required

The resource requires operator attention. This condition sometimes
generates an alarm, and the component that requires attention is colored
yellow in the tree pane and in the Physical and ServerNet views of the
view pane.

Service Required

The resource requires service. This condition generates an alarm, and the
component that requires service is colored red in the tree pane and in the
Physical and ServerNet views of the view pane.

Fabric State

Value

Meaning

Up

At least one of the processors on the local node can communicate with at least one
processor on one of the remote nodes.

Down

No processor on the local node can communicate with a processor on any remote node.
This value is the default.

Note: The Fabric state for a one-node ServerNet cluster is Down because

communication with processors in remote nodes is not possible.