Actions, Ccsa (common communication servernet adapter) cru, Attributes – HP NonStop G-Series User Manual

Page 82: Ccsa cru

Advertising
background image

Current Value

The current combined voltage of both the upper and lower cells of the
battery.

— If the Total Voltage falls below 42 volts, an alarm is generated.

— If the Total Voltage falls below the 39.6 volts, the battery is
disconnected.

Normal Maximum Value The maximum voltage that the battery can hold (60 volts).

Actions

Enable/Disable

Prepares the battery to supply power when AC power is unavailable. The battery must be enabled to
remain charged.

Parameter: Enabled (true = enabled, false = disabled)

CCSA (Common Communication ServerNet
Adapter) CRU

An adapter that allows PCI-based communications devices to connect to a server. A CCSA CRU can
hold up to four CCSA ServerNet addressable controllers (

SAC

s) with four ports each, providing up

to 16 links per adapter.

Location in OSM Tree: System > Group > Module > CCSA

Example: CCSA $ZZLAN.CCSA1 (2.1.53)

Attributes

CCSA

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Physical

Power State

Indication of whether the component is powered on.

Values

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.