Actions, Ssac (scsi sac), Ssac – HP NonStop G-Series User Manual

Page 167: One external

Advertising
background image

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Storage ASIC

Initialization State

The status of the storage ASIC in the CRU.

Values: Initialized, Not Initialized, Unknown

Actions

Replace

Launches the Replace SNDA guided procedure, which provides step-by-step instructions for
replacing the ServerNet/DA CRU.

Storage ASIC Initialization Test

Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.

This action is triggered automatically when a new CRU is inserted while OSM is running or when an
SCF STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.

Test Verify

Performs basic tests on the CRU. You can perform this action when the CRU is online.

SSAC (SCSI SAC)

The SCSI SAC (ServerNet addressable controller) is a SCSI plug-in card mounted on these devices:

Processor multifunction 2 (

PMF2

) CRU (external SCSI controller, SAC 3)

I/O multifunction (

IOMF2

) 2 CRU (external SCSI controller, SAC 3)

ServerNet/DA

CRU (There can be up to four SCSI SACs on each ServerNet/DA CRU.)

SCSI SACs are used for connecting external SCSI devices such as tape drives.

Location in OSM Tree: System > Group > Module > IOMF2 > SSAC

Example: SSAC (1.1.50.3)