Page 209: For the 6780 switch module

Advertising
background image

Current Value

The current temperature, in degrees Celsius (°C), inside the
enclosure of the module.

Normal Maximum Value

The maximum acceptable air intake temperature is 65 degrees
Celsius. If the temperature rises above 65 degrees, an alarm is
generated.

Actions

Blink All LEDs Off

Turns off the blinking of the fault LEDs on the switch logic board, PICs, power supplies and
fans.

SCF Equivalent: ALTER SWITCH, BLINK NONE

Blink All LEDs On

Causes the fault LEDs on the switch logic board, PICs, power supplies, and fans to blink on and
off.

SCF Equivalent: ALTER SWITCH, BLINK ALL

Connect to UPS

Starts a new Internet Explorer window and loads the default HTTP home page provided by the
UPS vendor.

Parameter: IP Address (the IP address of the UPS)

Replace

Invokes the Replace Switch Component guided procedure that helps to replace the switch
module.

Responsive Test

Tests the connectivity of the switch module from the local node.

Set Locator

Allows you to enter text to aid in locating or identifying the switch. This text is displayed as the
Locator attribute. These ASCII characters cannot be used in the Set Locator field: =, +, &, or %.
Also, copy and paste features do not work in this field. For more information, see

Specifying a

Cluster Switch Locator String

.

Parameter: Locator – Free-form text up to 64 characters long.