Attributes, Actions, Ups (ioam) – HP NonStop G-Series User Manual

Page 189

Advertising
background image

Attributes

Unknown CRU

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Physical

Power State Whether the component is powered on.

Values

Actions

None.

UPS (IOAM)

The uninterruptible power supply (UPS) unit for the IOAM enclosure.

Location in OSM Tree: System > Monitored Service LAN Devices > UPS

Example: UPS SDUPS

Attributes

UPS (IOAM)

Battery Status

Indicates the current status of the UPS battery. Possible values are
Normal and On Battery.

OSM displays a yellow alarm if the UPS goes On Battery (or starts
drawing power from the battery). This alarm goes away when the UPS
stops drawing power from the battery. OSM displays a red alarm when
the battery power is low.

Device Status

Indicates whether the UPS is up or down.

Identificaton Information

Displays additional information about the UPS as set by super-user in the
web interface (see the

Link to Web Interface

action). Up to 20 characters

are allowed.

Example: UPS Web Card

IP Address

The IP address of the UPS.

VA Rating

This is the apparent power rating of the UPS, expressed in Volt-Amperes.

Example: 12000 VA

UPS Location

Displays the physical location of the UPS as set by super-user in the the

Link to Web Interface

action.