Attributes, Actions, A servernet plug-in card – HP NonStop G-Series User Manual

Page 137: Which provides connectivity to, Plug-in cards

Advertising
background image

Replace

Launches the Replace MSEB guided procedure, which provides step-by-step instructions for
replacing the MSEB CRU.

PIC

A replaceable component of

MSEB

or

IOMF2

CRUs that provides connectivity to internal*

ServerNet fabrics.

* In port 6 of the MSEBs located in slot 51 and 52 of group 01 only, NNA-type ServerNet PICs can
be used to provide connectivity to external ServerNet fabrics.

Location in OSM Tree: System > Group > Module > IOMF2 > PIC

Example: PIC (1.1.52.1)

Attributes

PIC

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Physical

Type

Indication of the type of plug-in card.

Values: NNA, Serial Copper, ECL, Long-Haul Fiber, Short-Haul Fiber

Logical

Connector Number A unique number used to distinguish between plug-in cards on an MSEB CRU.

Actions

Clear Loopback Test

Clears the loopback test on a plug-in card (PIC). This action clears both the internal loopback test
initiated by the Internal Loopback Test action and the external loopback initiated by the guided
procedure for troubleshooting a ServerNet fabric. The action enables ServerNet ports so that packets
can be routed to the PIC from adjacent ports on the MSEB or IOMF2 and from the PIC in another
enclosure connected by the ServerNet cable to the PIC being tested. Use this action if the $ZCMOM
process terminates while a loopback test is being performed. This action is safe to use on any PIC
even if you are not sure a loopback test needs to be cleared on the PIC.

Enable Port