Absolute maximum ratings, Absolute maximum rat, Ings – Cirrus Logic CS42L73 User Manual
Page 20: Cs42l73 absolute maximum ratings

20
DS882F1
CS42L73
ABSOLUTE MAXIMUM RATINGS
Test Conditions: GND = AGND = PGND = CPGND = DGND = 0 V; all voltages are with respect to ground (GND).
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation
is not guaranteed at these extremes.
Notes:
4.
VP must be applied before VA is applied. VP must be removed after VA is removed.
5.
Any pin except supplies. Transient currents of up to ±100 mA on the analog input pins will not cause SCR latch-up.
6.
The maximum over/under voltage is limited by the input current.
7.
• V
FLT-x
is the applied voltage that causes a contention fault condition between its source and the CS42L73 output.
• ±VCPFILT are specified in
“DC Electrical Characteristics” on page 21
.
• The specification applies to both the signal and pseudodifferential reference pins, where applicable.
Parameters
Symbol
Min
Max
Units
DC Power Supply
Analog, Charge Pump, Digital Core (LDO fed),
Serial/Control/Digital-Mic Interfaces
Speakerphone Amplifiers, Mic Bias Generators
VA, VCP, VL
VP
-0.3
-0.3
2.22
5.6
V
V
Input Current
I
in
-
±10
mA
Voltages Applied to I/Os
External Voltage Applied
LINEINx, MICx, x_REF
to Analog Input
MIC2_SDET
V
IN-AI
V
IN-AI-SD
AGND – 0.3
PGND – 0.3
VA + 0.3
VP + 0.3
V
V
External Voltage
HPOUT, LINEOUT
Applied to Analog
EAROUT
SPKOUT, SPKLINEO, MICx_BIAS
V
FLT-HP_LINE
V
FLT-EAR
V
FLT-SPK_MB
-VCP_FILT – 0.3
AGND – 0.3
PGND – 0.3
+VCP_FILT + 0.3
VA + 0.3
VP + 0.3
V
V
V
External Voltage Applied to Digital Input
V
IN-DI
-0.3
VL + 0.3
V
External Voltage Applied to Digital Output
V
FLT-DO
-0.3
VL + 0.3
V
Temperature
Ambient Operating Temperature
Commercial: CWZR
(local to device, power applied)
T
A
-50
+110
°C
Storage Temperature (no power applied)
T
stg
-65
+150
°C