1 vp supply minimum voltage setting, 2 speakerphone light load mode enable, 3 mic bias output control – Cirrus Logic CS42L73 User Manual
Page 86: 4 short detect automatic mute control, P 86, Cs42l73

86
DS882F1
CS42L73
6.8
Output Load, Mic Bias, and MIC2 Short Detect Configuration (Address 0Ah)
6.8.1
VP Supply Minimum Voltage Setting
Configures the mic bias generation circuitry to accept the VP supply with the specified minimum value.
Notes:
• Refer to
“Recommended Operating Conditions” on page 19
for definitions of the lower and
higher minimum voltages.
• Note
explains how to use the VP_MIN control.
• See
“Mic BIAS Characteristics” on page 26
details how selecting the lower minimum volt-
age mode reduces the mic biases PSRR.
• If a mic path is active, it is recommended that the path be muted before changing the VP_
MIN setting to avoid audible artifacts.
6.8.2
Speakerphone Light Load Mode Enable
Configures the Speakerphone Driver to minimize power consumption. When the CS42L73 Speakerphone
output is used as a line driver to a light load, such as an external amplifier, quiescent power consumption
is reduced by setting this control.
Note: R
L
is defined in spec. table
“Serial Port-to-Mono Speakerphone Output Characteristics” on
6.8.3
Mic Bias Output Control
Sets the mode for the MIC1_BIAS and MIC2_BIAS device outputs.
Note: If either PDN or PDN_MICx_BIAS are set to powered down, the MICx_BIAS output will be Hi-Z,
regardless of the MIC_BIAS_CTRL setting.
6.8.4
Short Detect Automatic Mute Control
Configures the reaction to MIC2 Short Detect events.
7
6
5
4
3
2
1
0
Reserved
VP_MIN
SPK_LITE_
LOAD
MIC_BIAS_
CTRL
SDET_AMUTE
Reserved
Reserved
Reserved
VP_MIN
VP Supply Minimum Voltage
0
Lower Voltage
1
Higher Voltage
SPK_LITE_LOAD
Light Load Mode
Speakerphone Loading Applicable R
L
Range
0
Disabled
Heavy
R
L
R
L(max)
with SPK_LITE_LOAD = 0 b
1 Enabled
Light
R
L
R
L(min)
with SPK_LITE_LOAD = 1 b
MIC_BIAS_CTRL
Mic 1 and 2 Bias Status (When Powered Up)
0
“Mic BIAS Characteristics” on page 26
.
1
SDET_AMUTE
Reaction To MIC2 Short Detect Events
0
No reaction
1
MIC2 fed Input Path(s) is (are) automatically muted