SWITCHING SPECIFICATIONS—POWER, RESET, AND MASTER CLOCKS

Test conditions (unless otherwise specified): Connections to the CS42L73 are shown in the

“Typical Connection Diagram” on

page 17

; GND = AGND = PGND = CPGND = DGND = 0 V; all voltages are with respect to ground (GND); VA = VCP = VL =

1.80 V, VP = 3.70 V; T

A

= +25

C; Inputs: Logic 0 = GND, Logic 1 = VL.

Notes:

52. Refer to

Figure 10 on page 36

.

53. Maximum frequency for highest supported nominal rate is indicated. The supported nominal MCLK1/MCLK2 rates and

their associated configurations are found in section

“Internal Master Clock Generation” on page 42

. Likewise, the sup-

ported nominal serial port sample rates are found in section

“Serial Port Sample Rates and Master Mode Settings” on

page 53

.

Parameters

(Note 2)

Symbol Min

Max

Units

Power Supplies

(Note 52)

Power Supply Ramp Up/Down

t

pwr-rud

-

100

ms

Power Supply Ramp Skew

t

pwr-rs

-

1

s

Reset

(Note 52)

RESET low (Logic 0) Pulse Width

t

rlpw

1

-

ms

RESET Hold Time After Power Supplies Ramp Up

t

rh(PWR-RH)

1

-

ms

RESET Setup Time Before Power Supplies Ramp Down

t

rs(RL-PWR)

1

-

ms

Master Clocks

MCLK1 or MCLK2 Frequency

(Note 53)

-

-

38.5

MHz

MCLK1 or MCLK2 Duty Cycle

-

45

55

%

Power Supplies
(other than VP)

V

min

GND

Internal supplies stable

V

operating

t

rh(PWR-RH)

t

irs

Control port active

t

pwr-rs

t

rs(RL-PWR)

t

pwr-rs

RESET

t

pwr-rud

t

pwr-rud

t

pwr-rud

t

pwr-rud

1

st

Supply

Up

Last

Supply

Up

1

st

Supply

Down

Last

Supply

Down

Figure 10. Power and Reset Sequencing