13

Parameter reference

13.1

Parameters of the communication module

106

Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13

Parameter reference

This chapter supplements the parameter list and the table of attributes for the Inverter Drive 8400

contained in the software manual and in the »Engineer« online help by the parameters of the

communication module E84AYCEO (EtherNet/IP).

13.1

Parameters of the communication module

This chapter lists the parameters of the E84AYCEO communication module (EtherNet/IP) in

numerically ascending order.

C13000

C13001

Software manual/»Engineer« online help for Inverter Drives 8400
Here you will find general information on parameters.

Parameter | Name:

C13000 | IP Address

Data type: UNSIGNED_8

Index: 11575 = 0x2D37

Setting of the IP address

Setting the IP configuration of the Inverter Drive 8400 ( 42)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13000/1

192

IP address (most significant byte)

C13000/2

168

IP address

C13000/3

124

IP address

C13000/4

16

IP address (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13001 | Subnetwork Mask

Data type: UNSIGNED_8

Index: 11574 = 0x2D36

Setting of the subnet mask

Setting the IP configuration of the Inverter Drive 8400 ( 42)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13001/1

255

Subnet mask (most significant byte)

C13001/2

255

Subnet mask

C13001/3

255

Subnet mask

C13001/4

0

Subnet mask (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT