1 module status displays, Module status displays ( 90), Module status displays – Lenze E84AYCEO User Manual

Page 90: 11 diagnostics

Advertising
background image

11

Diagnostics

11.1

LED status displays

90

Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.1.1

Module status displays

Module states are indicated by the ST, ER and DE LEDs.

[11-1] LEDs ST, ER, DE

E84AYCEO007_a

ST

ER

DE

LED

Colour

Status

Description

ST

Green

On

The communication module is supplied with voltage and is connected to

the standard device.

Blinking

The communication module is supplied with voltage, but is not

connected to the standard device. (Standard device is switched off, in the

initialisation phase, or not available.)

ER

Red

On

An error has occurred in the communication module.

DE

Red

On

The communication module is not accepted by the basic device or the

basic device is not active (see notes in the documentation relating to the

basic device.)

250 ms

250 ms