Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

127

14

Implemented CIP™ objects

14.1

General CIP objects

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Instance attribute "Status" (attribute 5)

Supported service codes

Bits

Name

Description

0

Owned

The state ’1’ indicates that the device (or an object within the device) has

an owner. Within a master/slave model, the state ’1’ indicates that the

"predefined master/slave connection set" is assigned to a master.

Outside the master/slave model, it means "TBD".

1

-

Reserved (0)

2

Configured

The state ’1’ indicates that the activities the device application carries

out differ from the "out of box" standard configuration. This should not

comprise the configuration of communication.

3

-

Reserved (0)

4 ... 7

Extended Device Status

• 0000: Status is "self-testing" or unknown

• 0001: Firmware update is being carried out

• 0010: At least one faulty I/O connection

• 0011: No I/O connections available

• 0100: Non-volatile configuration is faulty

• 0101: "Major fault" (bit 10 or 11 is ’1’)

• 0110: At least one I/O connection is in the "run mode"

• 0111: At least one I/O connection is available, all are in the "idle

mode"

• 1000: Reserved

• 1001: Reserved

• 1010 ... 1111: Reserved / manufacturer-specific

8

Minor Recoverable Fault

The state ’1’ indicates that a "Minor Recoverable Fault" has occurred.

9

Minor Unrecoverable Fault

The state ’1’ indicates that a "Minor Unrecoverable Fault" has occurred.

10

Major Recoverable Fault

The state ’1’ indicates that a "Major Recoverable Fault" has occurred.

11

Major Unrecoverable Fault

The state ’1’ indicates that a "Major Unrecoverable Fault" has occurred.

12 ... 15

Extended Device Status 2

Reserved (0) / manufacturer-specific

Service code

[hex]

Name

Description

0x01

Get_Attributes_All

Outputs a list of the attributes and the attribute's values for

a certain object.

0x05

Reset

These reset service types are supported:

• 0: Mains switching (power off/on) is simulated.

• 1: The parameters of the device are reset to the Lenze

setting and mains switching (power off/on) is simulated.

0x0E

Get_Attribute_Single

Outputs the value of a certain attribute.