14

Implemented CIP™ objects

14.1

General CIP objects

130

Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Instance attributes for output data of the scanner

Assembly output objects (scanner to adapter) are assumed to have a 4-byte header (32-bit "run/idle

header"). When mapping the assemblies, this header will automatically be added to the data

stream by most Allen-Bradley PLC/SLC equipment.
If your PLC does not support this header (like the Rockwell PLCs do), add a preceding 32-bit header

to the output image.
You can then define the bit 0 of this header in the process image of your PLC:

• State ’0’: idle mode
• State ’1’: run mode

For the operation with Rockwell PLCs, adaptations are not required.
The

Lenze Class (104 / 0x68)

( 158)

provides the image of the output data of the scanner.

Attribute

ID

Service

Name

Data type

Value

3

Get / Set Data

ARRAY of

SINT / INT /

DINT

Max. 16 bytes from the scanner to the

adapter:

• 20 (0x14): Basic Speed Control Output

• 21 (0x15): Extended Speed Control

Output

• 22 (0x16): Speed and Torque Control

Output

• 23 (0x17): Extended Speed and Torque

Control Output

• 110 (0x6E): Custom Output

Instance attribute "Data" (attribute 3)

( 131)

4

Get

Size

UINT

Number of bytes in attribute 3 (Data)