2 protective insulation, Protective insulation, 4technical data – Lenze E84AYCEO User Manual

Page 17

Advertising
background image

Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

17

4

Technical data

4.2

Protective insulation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2

Protective insulation

Danger!

Dangerous voltage
If the Inverter Drives 8400 are operated on a phase-earthed mains with a rated mains

voltage of  400 V, external measures need to be implemented in order to ensure

protection against accidental contact.
Possible consequences:
Death or severe injuries
Protective measures:
If protection against accidental contact is required for the control terminals of the

inverter and the connections of the plugged device modules, ...

• a double isolating distance must exist.
• the components to be connected must be provided with the second isolating

distance.

Note!

The existing protective insulation in the Inverter Drives 8400 is implemented according

to EN 61800-5-1.