C13858, C13858 | ethernet port statistics, C13861 – Lenze E84AYCEO User Manual

Page 116: C13861 | cip module status, 13 parameter reference

Advertising
background image

13

Parameter reference

13.1

Parameters of the communication module

116

Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13858

C13861

Parameter | Name:

C13858 | Ethernet Port Statistics

Data type: UNSIGNED_32

Index: 10717 = 0x29DD

Display of statistical values for the data transfer via the Ethernet connections
Subcodes

Info

C13858/1

Ethernet port X259: RX

C13858/2

Ethernet port X259: RX CRC error

C13858/3

Ethernet port X259: RX discarded

C13858/4

Ethernet port X259: TX

C13858/5

Ethernet port X259: TX discarded

C13858/6

Ethernet port X260: RX

C13858/7

Ethernet port X260: RX CRC error

C13858/8

Ethernet port X260: RX discarded

C13858/9

Ethernet port X260: TX

C13858/10

Ethernet port X260: TX discarded

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13861 | CIP Module Status

Data type: UNSIGNED_16

Index: 10714 = 0x29DA

Display of the current CIP module status

(Instance attribute 8 (State) in the

Identity Object (1 / 0x01) ( 126)

)

• The status is also indicated via the MS LED.

LED status displays ( 89)

Selection list

(read only)

0 Nonexistent
1 Device Self Testing
2 Standby
3 Operational
4 Major Recoverable Fault
5 Major Unrecoverable Fault

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT