11 diagnostics – Lenze E84AYCEO User Manual

Page 93

Advertising
background image

Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

93

11

Diagnostics

11.1

LED status displays

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

NS

Green

Red

Off

Off

CIP network status: "No IP Address"

The communication module is not being supplied with voltage or has

not been given an IP address.

Off

On

CIP network status: "Duplicate IP"

The communication module is unable to gain access to the fieldbus (IP

address conflict).

Off

Blinking

CIP network status: "Connection Timeout"

A time-out is executed.

On

Off

CIP network status: "Connected"

The communication module is working perfectly and has established a

connection to the scanner.

Blinking

Off

CIP network status: "No Connections"

The communication module ...

• is working correctly;

• has been assigned an IP address;

• has not been integrated into the network by the scanner yet.

Blinking

Blinking

CIP network status: "Self-Test"

The communication module is currently undergoing a self-test.

LED

Colour / status

Description

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms