Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

LED

Colour / status

Description

MS

Green

Red

Off

Off

CIP module status: "Nonexistent"

The communication module is not being supplied with voltage.

Off

On

CIP module status: "Major Unrecoverable Fault"

The communication module has a fault that cannot be rectified.

The status is set if the pending status determining device error shows

the "System fault" response.

Off

Blinking

CIP module status: "Major Recoverable Fault"

The communication module has a fault that can be rectified.

The status is set if the pending status determining device error shows

the "Fault", "Trouble", "Quick stop by trouble", "Warning locked", or

"Warning" response.

On

Off

CIP module status: "Operational"

The communication module is working perfectly.

Blinking

Off

CIP module status: "Standby"

The communication module has not been completely configured or the

configuration is defective.

Blinking

Blinking

CIP module status: "Device Self Testing"

The communication module is currently undergoing a self-test.

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms